No. 3000 ~ 3999

3001: Out of memory (shared memory).

  • Cause: Insufficient shared memory remaining.

  • Action: To increase the shared memory space, specify a larger value for the TOTAL_SHM_SIZE parameter.

3002: Out of memory (unable to allocate %1$d bytes of shared pool memory).

  • Cause: Insufficient shared pool memory remaining.

  • Action: To increase the shared memory space, specify a larger value for the TOTAL_SHM_SIZE parameter.

3003: Out of memory (system memory).

  • Cause: The system memory is full.

  • Action: Increase the system memory space, or close other running programs.

3004: Unable to open log file.

  • Cause: Cannot open the log file.

  • Action: Check the log file path and permissions.

3005: Insufficient space in buffer.

  • Cause: Insufficient buffer space.

  • Action: Increase the size of the buffer.

3006: Feature not yet implemented.

  • Cause: This feature is not yet implemented.

  • Action: Check whether a feature which is not yet implemented was used.

3007: Environment variable (database home and database sid) is not set.

  • Cause: An environment variable (database home and database sid) has not been defined.

  • Action: Define the variable.

3009: Unable to change log directory because the target directory is the same as the old destination.

  • Cause: The target directory is the same as the log directory currently being used.

  • Action: Specify a directory that is different from the current log directory.

3010: Unable to change log directory because of a failure in renaming log file.

  • Cause: Unable to rename the log file. Refer to the server error log for more detail.

  • Action: Examine the log file permissions and check the server error log. For more information, contact the technical support team.

3011: Unable to change log directory because of a failure in generating new log file.

  • Cause: The target directory has insufficient space.

  • Action: Examine the target directory space and initial parameters such as LOG_TOTAL_SIZE_LIMIT. Ensure the directory has sufficient space by deleting or moving unnecessary files. For more information, contact the technical support team.

3012: Unable to change log directory.

  • Cause: An error occurred while remapping a new log file. Check the error log at server.

  • Action: Examine the error log in the server. For more information, contact the technical support team.

3013: Unable to change log directory because filenames conflict.

  • Cause: There is already a log file with identical name in the target directory.

  • Action: Modify the filename or remove the log file in the target directory.

3014: Unable to create a directory for the new log file.

  • Cause: Unable to create a directory for the new log file due to invalid path or authority.

  • Action: Check whether a path and its authority of the new log file are valid. Also examine the error log of the server. For more information, contact the technical support team.

3015: Type of the JSON value is different from expected type.

  • Cause: Type of the JSON value is different from expected type.

  • Action: Examine the error log in the server. For more information, contact the technical support team.

3016: Expected JSON key not found.

  • Cause: Expected JSON key not found.

  • Action: Check the inventory of Horde.

3017: Too many objects referred (%1$d).

  • Cause: Too many objects referred (%1$d).

  • Action: Contact the technical support team.

3018: Out of memory (unable to allocate %1$d bytes of shared pool memory for %2$s).

  • Cause: Insufficient shared pool memory remaining.

  • Action: To increase the shared memory space, specify a larger value for the TOTAL_SHM_SIZE parameter.

Last updated